当前位置:首页 > 科学研究 > 科技前沿 > 正文内容

NIST prototype design uses ultracold trapped atoms to measure pressure

RonWang7年前 (2018-10-20)科技前沿1161

Many semiconductor fabricators and research labs are under increasingpressure from, of all things, vacuum. These facilities need to remove greater amounts of gas molecules and particles from their setups as new technologies and processes demand lower and lower pressures. For example, the vacuum chambers in which microchip manufacturers lay down aseries of ultrathin layers of chemicals step by step—a process that must be utterly free of contaminants—operate at about one hundred-billionth of the air pressure at sea level. Some applications need pressures at least a thousand times lower than that, approaching the even more rarefied environments of the Moon and outer space.

NIST Design for portable cold-atom vacuum standard

Measuring and controlling vacuum at those levels is an exacting business in which accuracy is essential. Current technology usually relies on a device called an ion gauge. However, ion gauges require periodic recalibration and are not compatible with the new worldwide effort to base the International System of Units (SI) on fundamental, invariant constants and quantum phenomena. 

First, researchers attach the cold-atom vacuum standard (CAVS) device to the vacuum chamber they want to measure. When the CAVS and vacuum chamber reach equilibrium pressure, lithium atoms are introduced into the CAVS. As the atoms move into the device chamber, they are slowed by laser light and then captured by a combination of laser light and magnetic fields. This trapping process causes the atoms to fluoresce, emitting light in all directions. Some of the emitted light is captured by a detector. When a molecule of background gas collides with a trapped atom, it can knock the atom out of the trap. Every time an atom is lost from the trap, the total fluorescence diminishes. By measuring changes to the emitted light, researchers can measure the rate at which atoms are lost from thetrap, which provides a sensitive indicator of pressure in the chamber.

NowNIST scientists have designed a vacuum gauge that is small enough to deploy in commonly used vacuum chambers. It also meets Quantum SI criteria, meaning it requires no calibration, depends on fundamental constants of nature, reports the correct quantity or none at all, and has specified uncertainties that are suitable for its application. The new gauge tracks changes in the number of cold lithium atoms trapped by alaser and magnetic fields within the vacuum. The trapped atoms fluoresce as a result of the laser light.

Every time a cold atom is struck by one of the few molecules moving around in the vacuum chamber, the collision kicks the lithium atom out of the trap, decreasing the amount of fluorescent light emitted. A camera records the dimming. The faster the light dims, the more molecules are in the vacuum chamber, making the fluorescence level a sensitive measure of pressure.

The new portable system is the result of a NIST project to create a tabletop cold-atom vacuum standard (CAVS) that will be used to make measurements of fundamental atomic properties. While CAVS is too large for, and unsuited to, use outside the laboratory, the portable version, or p-CAVS, is designed to be a “drop-in” substitute for existing vacuum gauges.  

“Nobody has thought about how to miniaturize such a cold-atom vacuum gauge and what kinds of uncertainties it would entail,” said Stephen Eckel, one of the project scientists who in September described their design

in the journal Metrologia.“We are in the process of developing such a system that could potentially replace sensors now on the market, as well as figuring out how to operate and evaluate it.” Individual components are being tested,and a working prototype is expected in the near future.

The NIST design uses a newly developed variation on a staple technology of atomic physics: the magneto-optical trap (MOT). In a typical MOT, there are six laser beams—two opposing beams on each of three axes. Atoms placed in the trap are slowed when they absorb momentum from laser photons of exactly the right amount of energy, damping the atoms’ motion. To confine them in the desired location, the MOT contains a varying magnetic field, the strength of which is zero at the center and increases with distance outward. Atoms in higher-field areas are more susceptible to laser photons and are thus pushed inward.

NIST’s portable gauge uses only a single laser beam directed onto an optical component known as a diffraction grating, which splits the lightinto multiple beams coming from various angles. “Putting in laser beamsfrom six different directions makes the experiment really big and needsa lot of optics,” said Daniel Barker, another NIST project scientist. “Now you only need one laser beam that comes in and hits a diffraction grating. When the light is diffracted you get the other beams that you need to close the MOT and make the trap.” 

At that point, the atoms are only a few thousandths of a degree aboveabsolute zero. They are struck by ambient molecules, principally hydrogen—the dominant gas that remains after the vacuum chambers are baked and then pumped down to ultrahigh (UHV) or extreme-high vacuum (XHV). The UHV range includes the vacuum level around the International Space Station; XHV includes the even lower pressure levels above the Moon.

The use of lithium is another scientific innovation in the NIST design. Lithium is the third-lightest element and belongs to the group of alkali metals—including sodium, potassium, rubidium and cesium—which are comparatively easy to cool and trap. “Nobody to our knowledge has been thinking about a single-beam MOT for lithium,” Barker said. “Lots of people think about rubidium and cesium, but not too many about lithium. Yet it turns out that lithium is a much better sensor for vacuum.”

Among the advantages: The interaction dynamics between lithium atoms and hydrogen molecules can be calculated exactly from first principles. “That allows us to make a primary gauge that you don’t need to calibrate,” Eckel said. “Moreover, lithium has an extraordinarily low vapor pressure at room temperature (meaning it has a low tendency to change into a gaseous state). So, typically, the atom will make a singlepass through the MOT region and if it is not trapped it will hit a walland stay there forever. With rubidium or cesium, which have relative high vapor pressures at room temperature, eventually you will coat the walls of the vacuum chamber with enough rubidium or cesium metal that the coatings will start emitting atoms.

“In addition, lithium’s vapor pressure also remains low at 150 degrees Celsius, where people generally bake UHV and XHV chambers to remove water coatings on the stainless steel components. In that sense, you can still prepare the vacuum chamber through standard techniques, even with this gauge attached.”

UHV and XHV environments “are a critical part of the infrastructure in advanced manufacturing and research, from gravitational-wave detectors to quantum information science,” said James Fedchak, who oversees the project. “CAVS will be the first absolute sensor created that operates in this pressure regime. At present, engineers and scientists often use the experiment or process itself to determine the vacuum level, which is often a destructive test.”

“p-CAVS will enable researchers and manufacturers to accurately determine the vacuum level before the experiment or process begins,” said Fedchak. “It will also allow lower levels of vacuum to be accurately measured—levels which are becoming more and more important inareas such as quantum information science.”

Paper: S. Eckel, D.S. Barker, J.A. Fedchak, N.N. Klimov, E. Norrgard,J. Scherschligt, C. Makrides and E. Tiesinga. Challenges to miniaturizing cold atom technology for deployable vacuum metrology. Metrologia. Published online 14 September 2018. DOI: 10.1088/1681-7575/aadbe4

版权声明:本文为原创文章,版权归donstudio所有,欢迎分享本文,转载请保留出处!

本文链接:http://parentscn.com/?id=39

相关文章

液压快换接头技术现状及选型分析

液压快换接头技术现状及选型分析

本篇论文发表在 科技创新导报(Science and Technology Innovation Herald)2019年8月刊。文章液压快换接头的常用分类方式进行了概述,对其相关的国内外标准进行综合...

新型PTFE涂层O形圈的研究与应用

新型PTFE涂层O形圈的研究与应用

摘 要:针对O形圈在工业应用中遇到的问题和挑战,结合PTFE的独特性质,设计开发了PTFE涂层的O形圈新产品,并对产品进行关键技术指标的测试,讨论了该类产品在汽车制造、电子和半导体工业的应用,最后得出...

车联网仿真测试的研究与分析

车联网仿真测试的研究与分析

本文论述车联网行业技术发展的趋势,介绍了车联网仿真测试的方法和内容,对车联网仿真工具和仿真建模进行了详细研究,并通过仿真案例说明测试的意义。随着互联网技术的发展与人们对网络化生活的需求,汽车智能化成为...

液压与气动 2019,Volume 0, Issue 09

液压与气动 2019,Volume 0, Issue 09

《液压与气动》创刊于1977年,属技术类学术期刊,是由中国机械工业联合会主管,中国机械工程学会与北京机械工业自动化研究所联合主办,《液压与气动》编辑部出版的中文核心期刊,主要栏目包含专题、研究·设计、...

Gait Recognition 步态识别

Gait Recognition 步态识别

Gait as a BiometricGait – “A person’s manner of walking”–  Webster DefinitionIt is a non-contac...

Introduction to Robotics Mechanics and Control

Introduction to Robotics Mechanics and Control

本人从事汽车和机械设计多年,近几年开始研究机器人技术,在此我将分享我的机器人技术和人工智能领域的学习路径,分享心得。1. Introduction to Robotics Mechanics an...